LOW VOLTAGE SHUNT CAPACITORS
What if you never had to wait for months anymore in order to get your capacitors?
Our delivery time starts from 2 weeks*!
Main features of Gruppo Energia capacitors for Low Voltage applications:
– fully customizable to suit your needs;
– dry type;
– high quality (we are certified CE, VDE, UL, cULus, ISO, SASO, EAC).
Need assistance?
Do you need help in choosing the right capacitors for your needs? Contact us! Our technical department is always happy to help!
Alternatively, you can read our suggestions here.
*for certain products and depending on the period of the year.
Standards:
- DIN EN 60831-1 (VDE 0560-46): 2014-11; EN 60831-1:2014
- DIN EN 60831-2 (VDE 0560-47): 2014-11; EN 60831-2:2014
Origin: 100% made in Italy
OUR SERIES
- Intact Base (standard)
- Intact Plus (Heavy Duty)
- Intact AllPower (Extra Heavy Duty)
- Single Phase (standard)
RCM-INB-3
Three-phase power factor correction capacitors
Designed to be used in standard conditions, where the presence of non-linear loads is not significant.
NLL < 10%
Applications:
- Networks with non significant non-linear loads;
- Standard overcurrent;
- Standard operating temperature;
- Normal switching frequency;
- Standard life expectancy.
For more information, please consult the table below:
General | |
Voltage range | 220 V to 1000 V |
Frequency | 50 Hz / 60 Hz |
Power range | 1 kVar to 62,5 kVar |
Insulation level | 3/8 kV |
Dielectric | Al/Zn slope metallized polypropylene film, wave-cut |
Filling | gel-type polyurethane resin, Non-PCB |
Casing | sealed metal (aluminium) enclosure |
Operating conditions | |
Ambient temperature | min. -40°C / max. 55° C |
Overvoltage | Un +10% for 8 hrs. daily |
Overcurrent | up to 1,5 x In (including harmonics) |
Inrush current | up to 180 x In |
Service life | up to 100.000 hrs. |
Harmonic presence | NLL <10% |
Safety features | |
Safety | overpressure disconnector on three phases + incorporated fuses + self-healing + discharge resistor |
Protection type | IP 20 |
Other power and voltage levels are available upon request. For more information, don’t hesitate to contact us.
RCM-INP-3
Three-phase power factor correction capacitors (heavy duty)
Resistant to current overloads and designed to work in difficult conditions, even in case of a limited quantity of non-linear loads. The current resistance of the Intact Plus series is higher compared to the previous capacitor series.
NLL < 20%
Applications:
- Few non-linear loads;
- Significant overcurrent;
- High operating temperature;
- Significant switching frequency;
- Long life expectancy.
Please consult the table below:
General | |
Voltage range | 220 V to 1000 V |
Frequency | 50 Hz / 60 Hz |
Power range | 1 kVar to 50 kVar |
Insulation level | 3/8 kV |
Dielectric | Al/Zn slope metallized polypropylene film, wave-cut |
Filling |
gel-type polyurethane resin, Non-PCB |
Casing |
sealed metal (aluminium) enclosure |
Operating conditions | |
Ambient temperature | min. -40°C / max. 55° C |
Overvoltage | Un +10% for 8 hrs. daily |
Overcurrent | up to 1,8 x In (including harmonics) |
Inrush current | up to 250 x In |
Service life | up to 160.000 hrs. |
Harmonic presence | NLL <20% |
Safety features | |
Safety | overpressure disconnector on three phases + incorporated fuses + self-healing + discharge resistor |
Protection degree | IP 20 |
Other power and voltage levels are available upon request. For more information, don’t hesitate to contact us.
RCM-INA-3
Three-phase power factor correction capacitors (extra heavy duty)
Highly reliable capacitors for operation in harsh environments or when there is a significant level of non-linear loads. They are resistant to high overloads in current and voltage. Intact AllPower series is also resistant to high temperatures.
NLL <25%
Applications:
- Significant number of non-linear loads (up to 25%);
- Significant overcurrent;
- Extreme temperature conditions;
- Significant switching frequency;
- Extra long life expectancy.
For more information, please consult the table below:
General | |
Voltage range | 220 V to 1000 V |
Frequency | 50 Hz / 60 Hz |
Power range | 1 kVar to 50 kVar |
Insulation level | 3/8 kV |
Dielectric | Al/Zn slope metallized polypropylene film, wave-cut |
Filling | gel-type polyurethane resin, Non-PCB |
Casing | sealed metal (aluminium) enclosure |
Operating conditions | |
Ambient temperature | min. -45°C / max. 60° C |
Overvoltage | Un +10% continuous operation |
Overcurrent | up to 2,5 x In (including harmonics) |
Inrush current | up to 280 x In |
Service life | up to 180.000 hrs. |
Harmonic presence | NLL < 25% |
Safety features | |
Safety |
overpressure disconnector on three phases + incorporated fuses + self-healing + discharge resistor |
Protection degree |
IP 20 |
Other power and voltage levels are available upon request. For more information, don’t hesitate to contact us.
RCM-1:
Single-phase capacitors designed to be used in standard conditions, where the presence of non-linear loads is not significant.
NLL < 10%
Applications:
- Networks with non significant non-linear loads;
- Standard overcurrent;
- Standard operating temperature;
- Normal switching frequency;
- Standard life expectancy.
For more information, please consult the table below:
General | |
Voltage range | 220 V to 1000 V |
Frequency | 50 Hz / 60 Hz |
Power range | 0,25 kVar to 50 kVar |
Insulation level | 3/8 kV |
Casing | sealed metal (aluminium) enclosure |
Dielectric | Al/Zn slope metallized polypropylene film, wave-cut |
Filling | gel-type polyurethane resin, Non-PCB |
Operating conditions | |
Ambient temperature | min. -40°C / max. 55° C |
Overvoltage | Un +10% for 8 hrs. daily |
Overcurrent | up to 1,5 x In (including harmonics) |
Inrush current | up to 180 x In |
Service life | up to 100.000 hrs. |
Harmonic presence | NLL <10% |
Safety features | |
Safety | overpressure disconnector (discharge resistor available upon request) |
Protection degree | IP 20 |
Other power and voltage levels are available upon request. For more information, don’t hesitate to contact us.