ACTIVE HARMONIC FITERS & SVG
2 EASY-TO-USE TOOLS TO SOLVE POWER QUALITY PROBLEMS
Did you know that harmonic frequencies in the power grid are the main cause of power quality problems? They can dramatically shorten the life cycle of your equipment and cause delays in production.
Now you can easily solve these problems by using only one device that can provide:
- Harmonic compensation;
- Reactive power compensation;
- Phase balancing.
Standards:
- DIN EN 61000-4-7 (VDE 0847-4-7) : 2009-12
Origin: 100% made in Italy
GEAHF:
Benefits:
- Increase your savings thanks to a correct power factor, lower energy charges, reduced fuel consumption in generators.
- Avoid penalties: utility companies charge reactive power fees to consumers with low power factor. Thanks to our Active Filters, you can improve power factor and save up to 30%.
- Avoid delays of production. Our AHFs reduce the risk of equipment failure, increase operational reliability and protect sensitive electronics.
Gruppo Energia AHF are a completely assembled, ready-to-use and flexible solution.
Some applications:
- Renewable energy
- Textile industry
- UPS systems
- Oil and gas
- Electric furnaces, ball mills and similar applications
- Commercial and residential complexes
- Train applications
Please consult the table below for more information:
General | |
Installation | Cabinet/ wall-mounted/ tray |
HMI | Touch screen as standard equipment |
Power grid structure | 3P4L / 3P3L |
Protection rating | IP 20 (IP 54 upon request) |
Reactive power compensation | Capacitive and inductive |
Filtering range | 2-25 harmonic orders (2-50 harmonic orders upon request) |
Dynamic response time | <100 µs |
Full response time | <10 ms |
Communication interface | RS-485 |
Protocol | Modbus Protocol |
Operating conditions |
|
Operating voltage | 400 V – 690 V |
Input voltage range | 320 V – 790 V |
Frequency | 50 Hz/ 60 Hz |
Ambient temperature (C°) | min. -10° max. +40° C (the average daily temperature shouldn’t be higher than 35° C) |
Other configurations are available upon request. Contact us for more information.
GE-SVG3:
We are proud to show you our sensational Static Var Generator/Compensator and Active Load Balancer.
This two-in-one hybrid innovative technology solves unbalanced phases and performs PFC compensation.
SVG + Balance is the instantaneous and effective response to power quality problems in low or high voltage systems.
Consult the table below for more information:
General | |
Installation | Cabinet/ wall-mounted/ tray |
HMI | Touch screen as standard equipment |
Power grid structure | 3P4L / 3P3L |
Protection rating | IP 20 (IP54 upon request) |
Reactive power compensation | Capacitive and inductive |
Three-phase unbalance compensation | Yes |
Dynamic response time | <100 µs |
Full response time | <10 ms |
Communication interface | 1 way RS-485 |
Protocol | Modbus Protocol |
Operating conditions |
|
Operating voltage | 400 V – 690 V |
Input voltage range | 320 V – 790 V |
Frequency | 50 Hz/ 60 Hz |
Ambient temperature (C°) | min. -10° C max. +40° C(the average daily temperature shouldn’t be higher than 35°C) |
Other configurations are available upon request. Contact us for more information.